Keywords = گزینش پذیری
Chemical Engineering (Transport Phenomena, Unit Operations, and Process Systems)

Performance evaluation of Pebax/ deep eutectic solvent supported liquid membrane in carbon dioxide separation

Volume 8, Issue 2, Spring 2024, Pages 13-23

Abolfazl Ghavami, Reza Abedini

Abstract Abstract:

Research subject:

The use of deep eutectic solvents (DES) as an effective approach to enhance the performance of polymer membranes in CO2 gas separation has gained significant attention. Membranes modified with DES are referred to as supported liquid membranes (SLMs).

Research approach:

In this study, two-component (choline chloride/urea) and three-component (choline chloride/urea/DBU) DES were used to improve the efficiency of Pebax-1657 (poly(ether-block-amide)) membranes for separating CO2 from CH4 and N2 gases. Gas permeability tests conducted at 2 bar pressure and 30 °C compared pure membranes with membranes enhanced by 10 wt.% of the two-component DES and 10 wt.% of the three-component DES.

Results:

Results showed that the CO2 permeability increased from 3.77 barrer for the pure membrane to 4.96 barrer for the 10 wt.% DES two-component membrane, and to 7.101 barrer for the 10 wt.% DES-DBU three-component membrane. The CO2/N2 and CO2/CH4 selectivities improved from 20.32 and 11.36 for the pure membrane to 38.56 and 13.77 for the DES two-component membrane, and to 40.68 and 14.32 for DES-DBU three-component membrane, respectively. Moreover, with an increase in feed pressure from 2 bar to 6 and 10 bar, the membrane performance improved. At 10 bar, the CO2 permeability for the 10 wt.% DES three-component membrane increased to 16.28 barrer, while the CO2/N2 and CO2/CH4 selectivities rose to 56.13 and 20.60, respectively. Since the DES-DBU three-component membrane showed better performance than the DES two-component membrane and the pure membrane, various weight percentages of this composition were used to further enhance the Pebax polymer membrane. The results indicated that the membrane containing 20 wt.% of the DES-DBU three-component exhibited the best performance among all tested membranes. At 2 bar pressure and 30 °C, this membrane increased CO2 permeability to 13.88 barrer and CO2/N2 and CO2/CH4 selectivities to 51.46 and 18.80, respectively. Furthermore, at 10 bar pressure, the CO2 permeability reached 21.25 barrer, while the CO2/N2 and CO2/CH4 selectivities improved to 40.66 and 60.25, respectively. Ultimately, this membrane, compared to other studies, has successfully surpassed the Robeson limit, demonstrating its high potential for applications related to CO2 gas separation.

Biomedical Engineering, Drug Delivery, and Biotechnology

Investigation of performance of Pebax/ Poly(vinyl alcohol) blend membrane for carbon dioxide separation from nitrogen

Volume 3, Issue 4, Winter 2020, Pages 57-71

Mina Kheirtalab, Reza Abedini, Mohsen Ghorbani

Abstract Research subject: Selectivity and permeability are the major parameters of polymeric membranes in gas separation process. Hence, nowadays in order to improve aforementioned parameters, modification and enhancement issues for such membrane have been highly noticed.
Research approach: In this study, in order to improve the performance of polymeric membranes, the two-component blend membranes containing Pebax®1657 and PVA were synthesized for CO2 separation. The effect of different PVA concentrations within the Pebax matrix on structure, morphology and gas separation properties of resultant membranes was investigated. The chemical bonds, crystallinity and cross-sectional morphology studied through, Fourier transform infrared (FTIR), differential scanning calorimetry (DSC) and scanning electron microscopy (SEM), and were utilized.
Main results: The results of the thermal analysis indicated an increase in crystallinity and also glass transition temperature in presence of 5 – 15 wt.% PVA, while the membrane crystallinity decreased by increasing the PVA content up to 20 wt.%. FESEM images demonstrated a uniform cross-section without any cracks and defects for neat Pebax membrane but by adding PVA to Pebax matrix, appeared cracks and cave structures on the cross- section of blend membranes. The CO2/CH4 separation performance of membranes was measured using a constant volume set up at 30°C and feed pressure of 2, 6 and 10 bar. The obtained results revealed that the CO2 permeability in blend membranes improved as the PVA content increased within the membrane. The best obtained CO2 permeability was 204.64 Barrer which gained by Pebax/PVA (20wt.%) at feed pressure of 10 bar. Moreover, the highest selectivity of CO2/N2 for blend membrane with 15 wt.% of PVA was about 100.21 at 10 bar and 30°C.